{"id":465,"date":"2021-01-29T22:08:31","date_gmt":"2021-01-29T22:08:31","guid":{"rendered":"http:\/\/scopedetective.com\/?p=465"},"modified":"2021-01-29T22:09:33","modified_gmt":"2021-01-29T22:09:33","slug":"how-to-use-a-microscope","status":"publish","type":"post","link":"https:\/\/scopedetective.com\/how-to-use-a-microscope\/","title":{"rendered":"How to use a Microscope (7-Step Beginners Guide)"},"content":{"rendered":"\n

\"howThere are two key reasons you need to follow a clear procedure when using a microscope:<\/p>\n

    \n
  1. So you Succeed in your Projects:<\/strong> Finding focus on your specimen isn\u2019t as easy as it looks! But if you follow the procedure outlined in this article it will maximize your chances of zeroing in on your specimen to achieve success in your projects.<\/li>\n
  2. So you don\u2019t Damage your Microscope:<\/strong> But a microscope also contains many delicate parts. Careful preparation, use and storage is very important for ensuring you don\u2019t damage the equipment.<\/li>\n<\/ol>\n

    In this article, I\u2019ll provide a visual walk-through of the steps required for using a microscope safely and effectively.<\/p>\n\n

    How to use a Microscope Properly<\/h2>\n

    1. Transporting and Unpacking<\/h3>\n

    Chances are your microscope will be in storage or in its box when you start the project.<\/p>\n

    When you carry the microscope, try to carry it in two hands. Place one hand under the base and the other on the arm of the microscope. Try not to put your fingers on any of the lenses or the microscope\u2019s stage. Also try to hold the microscope flat, especially if there are any loose parts or slides on the microscope.<\/p>\n

    When unpacking the microscope, make sure all the parts are in their right place. The most common things that are missing are the objective lenses, eyepieces, and the head, which is often removed for storage. If you\u2019d like a walkthrough of microscope setup, see here.<\/p>\n

    2. Dim the Light, Turn it On, Increase Light Intensity<\/h3>\n

    Compound light microscopes have a sub-stage light. This light is usually controlled by a switch and dimmer on the right-hand side of the base of the microscope. In the image below, the switch is highlighted by the red square and the dimmer is highlighted by the red circle:<\/p>\n

    <\/p>\n

    Make sure you scroll that dimmer right to the lowest possible point before plugging the microscope into the wall and flicking the light switch.<\/p>\n

    The number 1 reason fuses blow on microscope lights is that you turn the light on while it\u2019s on the fullest setting.<\/p>\n

    The safest way to do it to prolong the lifespan of your light is to turn the light on while it\u2019s fully dimmed, then slowly increase the light intensity over the span of about 3 \u2013 5 seconds. This decreases the chances of the fuse blowing.<\/p>\n

    3. Fully Lower the Stage<\/h3>\n

    To start your experiment, use the coarse focus knob to lower the microscope stage to the very lowest position. Usually you can do this by rotating the coarse focus knob on the right-hand side near the base of the microscope arm towards you.<\/p>\n

    Below is an image the focus knobs labelled. You’ll want to use the focus knob:<\/p>\n

    <\/p>\n

    Most microscopes have ‘coarse focus’ which is adjusted by the base of the focus knob. This one adjusts the microscope stage faster. There is also a ‘fine focus’ knob which is adjusted by the tip of the focus knob and moves the stage small distances to get perfect focus at higher magnifications.<\/p>\n

    4. Place your Slide on the Stage and Center it.<\/h3>\n

    For your experiment, you should have either a prepared slide or a blank slide with a drop of your specimen placed in the middle.<\/p>\n

    This step involves placing that slide onto the stage correctly.<\/p>\n

    Your stage will either have a pinch clip that holds the slide from the side, or two overhead clips to pin the slide into place.<\/p>\n

    Insert the microscope slide onto the stage and clip it in.<\/p>\n

    Once it\u2019s inserted, you will likely need to do some stage adjustments to ensure the slide is directly above the light that is projecting up from the sub-stage lighting mechanism (usually an Abbe condenser).<\/p>\n

    If you have a mechanical stage<\/a>, you can use the knobs below the stage to center the slide. If you have a fixed stage, you\u2019ll need to use your fingers to center the slide on the stage.<\/p>\n

    5. Set your Red 4x Scanning Objective into Place and Raise the Stage using the Coarse Focus Knob<\/h3>\n

    You will see your microscope has one lens that has a red stripe on it. This is your scanning objective, which is the lowest power of all the objectives on the microscope turret:<\/p>\n

    <\/p>\n

    This is the best lens to start with. It will allow you to get rough focus on the specimen before heading up to higher power, but also let you literally \u2018scan\u2019 the slide to re-center it before heading to the higher power.<\/p>\n

    Once the red objective is set directly above the specimen (you\u2019ll feel a \u2018click\u2019), you can use the coarse focus knob<\/a> to raise the stage.<\/p>\n

    The red 4x lens is the only time you should use the coarse focus knob.<\/p>\n

    As the stage raises, you\u2019ll slowly start to see the specimen come into focus. Stop once it is focused.<\/p>\n

    6. Rotate your Objective Turret to the Yellow Low Power Lens (10x)<\/h3>\n

    Most microscopes will have 3 or 4 objectives. For the follow-up steps, you\u2019ll want to rotate your microscope up in power from one objective to the next.<\/p>\n

    Here is the usual range:<\/p>\n\n\n\n\n\n\n\n
    \n

    Objective Lens Band Color<\/strong><\/p>\n<\/td>\n

    \n

    Magnification<\/strong><\/p>\n<\/td>\n

    \n

    Common Lens Name<\/strong><\/p>\n<\/td>\n<\/tr>\n

    \n

    Red<\/p>\n<\/td>\n

    \n

    4x<\/p>\n<\/td>\n

    \n

    Scanning Lens<\/p>\n<\/td>\n<\/tr>\n

    \n

    Yellow<\/p>\n<\/td>\n

    \n

    10x<\/p>\n<\/td>\n

    \n

    Low Power<\/p>\n<\/td>\n<\/tr>\n

    \n

    Light Blue<\/p>\n<\/td>\n

    \n

    40x \u2013 50x<\/p>\n<\/td>\n

    \n

    High Power<\/p>\n<\/td>\n<\/tr>\n

    \n

    White<\/p>\n<\/td>\n

    \n

    100x \u2013 250x<\/p>\n<\/td>\n

    \n

    Oil Immersion<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

    This isn\u2019t set in stone \u2013 some microscopes have different magnifications, but the above is a general average and the most common magnification levels.<\/p>\n

    So, for most people this step will involve rotating from the objective with the red stripe to the objective with the yellow stripe.<\/p>\n

    Once you\u2019re set into the yellow objective, you\u2019ll likely notice the focus has gone foggy again. Slowly rotate the fine focus knob<\/strong> until the focus is back to perfect.<\/p>\n

    7. Re-Center the Specimen<\/h3>\n

    Between each time you increase magnification, make sure you re-center the specimen. If you don\u2019t, you\u2019ll likely lose your specimen each time you go up a magnification level.<\/p>\n

    At some point, you\u2019ll realize you\u2019re at the maximum magnification level you really need. If you step up another level, focus, lighting and size will be out. Perhaps you won\u2019t be able to see the whole specimen, for example.<\/p>\n

    When you\u2019re at this point, you might want to step back to a lower power lens for the best view.<\/p>\n

    You\u2019re done! Enjoy looking at your specimen.<\/p>\n

    Advanced Adjustments<\/h2>\n

    To further improve your viewing experience, you can do a few of the following advanced steps:<\/p>\n